Inverse design of composite turbine blade circular coolant flow passages Article

Chiang, TL, Dulikravich, GS. (1986). Inverse design of composite turbine blade circular coolant flow passages . 108(2), 275-282. 10.1115/1.3262048

cited authors

  • Chiang, TL; Dulikravich, GS

abstract

  • An inverse design and optimization method is developed to determine the proper size and location of the circular holes (coolant flow passages) in a composite turbine blade. The temperature distributions specified on the outer blade surface and on the surfaces of the inner holes can be prescribed a priori. In addition, heat flux distribution on the outer blade surface can be prescribed and iteratively enforced using optimization procedures. The prescribed heat flux distribution on theouter surface is iteratively approached by using the Sequential Unconstrained Minimization Technique (SUMT) to adjust the sizes and locations of the initially guessed circular holes. During each optimization iteration, a two-dimensional heat conduction equation is solved using directBoundary Element Method (BEM) with linear temperature singularity distribution. For manufacturing purposes the additional constraints are enforced assuring the minimal prescribed blade wall thickness and spacing between the walls of two neighboring holes. The method is applicable to both single material (homogeneous) and coated (composite) turbine blades. Three different cases were tested to prove the feasibility and the accuracy of the method. © 1986 ASME.

publication date

  • January 1, 1986

Digital Object Identifier (DOI)

start page

  • 275

end page

  • 282

volume

  • 108

issue

  • 2