Wireless power transmission to sensors embedded in concrete via magnetic resonance Conference

Jonah, O, Georgakopoulos, SV. (2011). Wireless power transmission to sensors embedded in concrete via magnetic resonance . 10.1109/WAMICON.2011.5872857

cited authors

  • Jonah, O; Georgakopoulos, SV

abstract

  • The feasibility of efficient wireless power transfer through Strongly Coupled Magnetic Resonance (SCMR) in non-homogenous interface such as air-concrete is studied here. Specifically, the efficiency of wireless power transmission from a source in air to a sensor embedded in concrete via strongly coupled magnetic resonance is analyzed. The concrete material is modeled for various humidity levels using the extended Debye's model. The efficiency of the SCMR is also analyzed for various depths inside the concrete. © 2011 IEEE.

publication date

  • July 11, 2011

Digital Object Identifier (DOI)

International Standard Book Number (ISBN) 13