The thermal performance of heat pipes with localized heat input Article

Cao, Y, Faghri, A, Mahefkey, ET. (1989). The thermal performance of heat pipes with localized heat input . INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 32(7), 1279-1287. 10.1016/0017-9310(89)90028-8

cited authors

  • Cao, Y; Faghri, A; Mahefkey, ET

authors

abstract

  • The performance of heat pipes with localized heat input including the effects of axial and circumferential heat conduction under high and low working temperatures is investigated. The numerical results show that when heat pipes are spot heated, the peak temperature of the wall is greatly reduced and the surface can be protected from being burned out by the high heat flux. The boiling limitation becomes the most important limitation for this type of heat pipe. Numerical results for block heating a heat pipe with low working temperatures indicate a good agreement with existing experimental data. It is also shown that most of the input heat passes through the wall beneath the heated block. © 1989.

publication date

  • January 1, 1989

Digital Object Identifier (DOI)

start page

  • 1279

end page

  • 1287

volume

  • 32

issue

  • 7